|
Who's Online
There currently are 5695 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
TV-13143 TV-13143W
ELECTRICAL ADJUSTMENTS
2-3: RF AGC 1. Receive the VHF HIGH (63dB). 2. Connect the digital voltmeter between the pin 5 of CP351 and the pin 1 (GND) of CP351. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (02) on the remote control to select �RF AGC�. 4. Press the VOL. UP/DOWN button on the remote control until the digital voltmeter is 2.9 ± 0.05V. 2-8: HORIZONTAL PHASE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (05) on the remote control to select �H PHASE�. 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-9: VERTICAL SHIFT 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (07) on the remote control to select �V SHIFT�. 4. Check if the step No. of V SHIFT is �3�. 5. Adjust the VR401 until the horizontal line becomes fit to the notch of the shadow mask. 2-10: VERTICAL SIZE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (06) on the remote control to select �V SIZE�. 4. Adjust by using the VOL. UP/DOWN button on the remote control so that the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 2-11: SUB BRIGHTNESS 1. Receive the monoscope pattern. (RF Input) 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (13) on the remote control to select �BRIGHTNESS�. 4. Press the VOL. UP/DOWN button on the remote control until the white 10% is starting to be visible. 5. Receive the monoscope pattern. (Audio Video Input) 6. Press the INPUT button on the remote control to set to the AV mode. Then perform the above adjustments 2~4. 2-12: SUB CONTRAST 1. Activate the adjustment mode display of Fig. 1-1 and press the channel button (14) on the remote control to select �CONTRAST�. 2. Press the VOL. UP/DOWN button on the remote control until the contrast step No. becomes �32�. 3. Press the INPUT button on the remote control to set to the AV mode. Then perform the above adjustments 1~2.
(TV SECTION)
2-4: CONSTANT VOLTAGE 1. Connect the digital voltmeter to the TP601 (R520). 2. Set condition is AV MODE without signal. 3. Using the remote control, set the brightness and contrast to normal position. 4. Adjust the VR502 until the DC voltage is 135 ± 0.5V. 2-5: CUT OFF 1. Adjust the unit to the following settings. R CUT OFF=128, G CUT OFF=128, B CUT OFF=128, BRIGHTNESS=128, CONTRAST=100 2. Place the set with Aging Test for more than 15 minutes. 3. Set condition is AV MODE without signal. 4. Using the remote control, set the brightness and contrast to normal position. 5. Activate the adjustment mode display of Fig. 1-1 and press the channel button (01) on the remote control to select �CUT OFF�. 6. Adjust the Screen Volume until a dim raster is obtained. 2-6: WHITE BALANCE NOTE: Adjust after performing CUT OFF adjustment. 1. Place the set with Aging Test for more than 15 minutes. 2. Receive the gray scale pattern from the Pattern Generator. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (10) on the remote control to select �R CUT OFF�. 5. Press the CH. UP/DOWN button on the remote control to select the �R CUT OFF�, �G CUT OFF�, �B CUT OFF�, �R DRIVE� or �B DRIVE�. 6. Adjust the VOL. UP/DOWN button on the remote control to whiten the R CUT OFF, G CUT OFF, B CUT OFF, R DRIVE, and B DRIVE at each step tone sections equally. 7. Perform the above adjustments 5 and 6 until the white color is looked like a white. 2-7: FOCUS 1. Receive the monoscope pattern. 2. Turn the Focus Volume fully counterclockwise once. 3. Adjust the Focus Volume until picture is distinct.
No. 51988
27
$4.99 TV-13143 JVC Owner's Manual Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
|
|
|
> |
|