Who's Online
There currently are 5997 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
;
High quality scan of original Service Manual. Everything´s fine!
;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
;
High quality scan of service manual. I am satisfied!
(5)
Push the anode cap with your thumb in the direction of arrow 1 as shown in the figure, then lift the cap in the direction of arrow 2 to release the hook on one side. (See Fig. 2-3)
1
Anode cap
2 1
CRT
Hook
CRT Hook Fig. 2-3
(6)
Turn over the anode cap on the side where the hook was released and pull out the cap in the direction opposite to that on which the cap was pushed. (See Fig. 2-4) Caution : Do not pull out the anode cap straight up. : Do not pull the cap forcibly. After removing the cap, check that the hook is not deformed.
Anode cap Pull out CRT Anode button Hook Fig. 2-4
3.
ANODE CAP REINSTALLTION
Observe the cautions carefully so that no accident occurs due to a defect in installing the anode cap and so it does not come off. 2-1. Caution before Reinstalling Never turn the anode cap after installing it Never re-use the hook when it has been deformed (1) If the anode cap is turned after it is installed, it may come off. Therefore, arrange the high-voltage cable before attaching the anode cap. (See Fig. 3-1) If you have attached the anode cap before arranging the high-voltage cable, arrange the cable carefully so the cap does not turn.
Anode cap Left Right
Fig. 3-1
(2)
3-2. Anode cap reinstallation (1) Use a clean cloth moistened slightly with alcohol to clean the installation section. (See Fig. 3-2) Caution : Check that the installation section is free from dust, foreign matter, etc. Coat the anode cap installation circumference with an appropriate amount of the specified silicone grease (KS-650N). Caution : Be careful that silicone grease does not enter the anode button.
Anode button
(2)
Installation section
Fig. 3-2