UX-P38V Removing the flywheel (See Fig. 8 & 9)
Flywheel R Flywheel L
1. Remove the head amp. and mechanism control board. 2. Remove the capstan motor assembly. 3. After turning over the cassette mechanism, remove the slit washers "a" and "b" fixing the capstan shafts R and L, and pull out the flywheels R and L respectively from behind the cassette mechanism.
a
Slit washer "a"
b
Slit washer "b"
Fig. 8
Flywheel R
Flywheel L
Fig. 9
Removing the reel pulse board and solenoid (See Fig. 10)
1. Remove the five pawls (c, d, e, f, g) retaining the reel pulse board. 2. From the surface of the reel pulse board parts, remove the two pawls h and i retaining the solenoid.
c hi
Solenoid
d
e
f
g
Reel pulse board
Solenoid
Fig. 10
1-14
|
|
 |
> |
|