Hello.
This paper enable me, to bring this lovley Scope into Function.
Without this Page, i have no cance to make this finish.
Hans M. Knoll Germany
;
I used for first time this the wheat and am very thanked
;
This manual was exactly what i needed and could not find elsewhere. Price is not too high. Great !
;
ecelent I was reciver the service manual soon I fell so happy very complete 100% positive all by this store tanks atte Luis salazar
;
A great copy of the manual, and the only one I could find anywhere on the net! The circuit diagrams are easily readable, all component values marked and easy to see. A highly appreciated download!
MATSUI VP 9505
Matrix
Item See Model Book
6 6 6 Deck Exploded View ............................................................................ VXA 1105 Deck Alignment .................................................................................... VXA 1105 Deck Adjustment .................................................................................. VXA 1105
1
Head Amp Diagram
Data Input
NOTE: Before performing of each adjustments, input the data as shown in Table 1. If there is an error in the data, the unit may indicate malfunction. INSTRUCTIONS 1. Press the Power button from Power-Off on the unit while pressing the AUTO key (ATR) on the Supplied Remote Control. The Initial Set Mode indicator will appear and the Address will blink. (Refer to Fig. 1) NOTE: If the Auto Set Up Function is working, the Initial Set Mode doesn�t work. In this case, release the Function or wait until the Function goes to end. Release Method: Play back a video tape. 2. Adjust the Address with the SET + or - button of Supplied Remote Control and press the ENTER button. The Data will blink. (Refer to Table 1) 3. Adjust the Data with the SET + or - button of Supplied Remote Control and press the ENTER button. 4. Repeat the above steps 2 and 3 and input the Datas into the each Address. 5. After the Data input, turn off the Power.
Fig. 1
ADDRESS INI INI INI ED EE EF DATA 04 48
INI F0
INI F1
INI F2
INI F3
INI F4
INI F5
INI F6
INI F7
INI F8
INI F9
INI FA
INI FB
INI FC
INI FD
INI FE
D4
00
02
05
40
00
00
00
87
05
00
A0
ED 0F
E6
0E
Table 1
|
|
|
> |
|