Who's Online
There currently are 5962 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This was a hard to find manual. When I did find it , some sites wanted way too much for the file.
Owner-manual .com had it for a really reasonable price. Not only that but it was sent very quickly and was a quality scanned document, unlike some others I purchased from a different site.
Good job guys!!
Larry
;
Fast and courteous service. Product delivered as described. Thank you.
;
Last week I bought a second hand Panasonic AG-7500 SVHS Hi-Fi Video Cassette Recorder. It is a professional machine with many video and audio options. I feared it would be a huge quest to find a manual. I was delighted when I found owner-manuals.com. After payment I received the file to download the next day already. The quality is great. I am very happy. Thanks!
;
The owner's manual/operating instructions that I purchased was the original factory document and it was in at least three and maybe more languages. I no longer have it because I sold the tape recorder and included the owner's manual/operating instructions and a service/repair manual that I bought on ebay for the new owner.
;
This manual is very useful. Because pioneer sx-q180 is unhandy to use without manual.
REC ONLY: Only alarm recording will start and monitors will keep displaying the current sequence/spot images. Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF: An alarm input is not accepted via the ALARM port. The factory default setting is ON. Each alarm input's polarity is configurable in the submenu. Set ALARM PORT to ON or REC ONLY, and press the CAM (SET) button. 440 ALARM INPUT (ALARM PORT) will appear on the monitor.
440 ALARM INPUT(ALARM PORT) SWITCHER=SLAVE1(1 of 5) 1 2 3 4 5 6 7 8 NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN OPEN 9 10 11 12 13 14 15 16 NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN TIME ADJUST
Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF: An alarm input is not accepted via the SERIAL port. The factory default setting is ON. 460 MUX MOTION DET MUX This stands for that the unit�s motion detector is activated when a camera detects the brightness-level change and transmit an alarm signal. ON: The alarm-associated sequence/spot image is displayed on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY: Only alarm recording will start and monitors will keep displaying the current sequence/spot images. Notes: � If the Multiplexer board is not installed in the unit, you cannot enter the submenu of 460 MUX MOTION DET. � You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF: An alarm input is not accepted by the motion detector.
Move the cursor and press the CAM (SET) button to go into the menu. SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. After designating the unit, select the desired polarity for ALARM 1 to 16. NORMALLY OPEN: Normally Open contact is activated for the alarm input signal. NORMALLY CLOSE: Normally Close contact is activated for the alarm input signal. TIME ADJUST: This polarity enables the input of the time adjusting signal. The factory default setting is N. O.
To configure where to activate the motion detector, set MUX MOTION DET to ON or REC ONLY, and press the CAM (SET) button. The live image will be displayed. Up to 4 motion-detection areas are configured for each camera channel. Note: Black image will be displayed on the monitor if the currently selected channel has no camera connection. A �+� mark appears at the center of the monitor.
Logical camera number and sensitivity C01 LOW
+
Note: In the master-slave connection, time setting of every unit can be synchronized when the time adjusting signal is input to any unit. 450 SERIAL PORT This stands for that an alarm input is accepted via the SERIAL port. ON: The alarm-associated sequence/spot image is displayed on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY: Only alarm recording will start and monitors will keep displaying the current sequence/spot images.
Mark
The following is the setting procedure.
69
|
|
|
> |
|