The service manual was very usable and clear enough to see the individual values of all of the components (unlike some of the service manuals I have gotten in the past from web sites similar to this one). The price was right and the information was greatly appreciated. It helped me with an otherwise very difficult repair. It was much needed and appreciated. A faster turn around on my order would be nice, but I understand the constraints on your staff's time. Thank you for your service.
;
Excellent manual. Helped me out with disassembling and troubleshooting my projector.
;
thanks you are the best.Very good detail, Quick service response. A useful service manual with all details.
;
Great service!!! Polecam gorąco wszystkim zainteresowanym
XR-A660, XR-A330
Recording Adjustment
(1) Bias Oscillation Frequency Adjustment
Step Mode Input Signal/ Test Tape Load the STD-632 test tape and set the recording mode. Adjusting Points Deck II DECK I    L2801 (AF Assy) Measurement Points    Between A point in Fig.7 and GND. Adjustment Value Oscillation frequency to be 105.0kHz ± 2kHz. Remarks If the REC/STOP button for four seconds while the power is in STAND BY mode, the frequency will decrease 2 to 3 kHz.
1
REC
(2) Recording Bias Adjustment
� Since this adjustment affects recording bias, prevent distortion from increasing due to underbias.
Step Mode Input Signal/Test Tape Input a 315Hz signal to the AUX terminal and set the input selector to AUX. Adjusting Points Deck II DECK I Deck II DECK I    Input signal level    VR2801(Lch) VR2802(Rch) Measurement Points TAPE TEST POINT (L, Rch) (AF Assy) TAPE TEST POINT (L, Rch) (AF Assy) Adjustment Value Remarks
1
REC
� 23.7dBV
2
Load the STD-632 test tape and REC � record/playback the 315Hz and PLAY 10kHz signals. (see the Note below)
Repeat adjustment until playback level of the 10kHz signal is within 0 ± 0.5dB from that of the 315Hz signal.
Note : Set the 10kHz input signal level to the same value as the 315Hz input signal level of step 1.
(3) Recording Level Adjustment
Step Mode Input Signal/Test Tape Input a 315Hz signal to the AUX terminal and set the input selector to AUX. Adjusting Points Deck II Input signal level DECK I Deck II DECK I    VR2301(Lch) VR2302(Rch) Measurement Points TAPE TEST POINT (L, Rch) (AF Assy) TAPE TEST POINT (L, Rch) (AF Assy) Adjustment Value Remarks
1
REC
�
7.7dBV
2
Load the STD-632 test tape and REC � record/playback the 315Hz PLAY signal.
Repeat recording, playback and adjustment until playback level of the 315Hz signal becomes � 7.7dBV.
(4) ALC Operation Check
Step 1 2 REC/ PAUSE Mode Input Signal/Test Tape Input a 315Hz signal to the AUX terminal and set the input selector to AUX. Adjusting Points Input signal level Set to a level +10dB adove the input level at step1. Measurement Points TAPE TEST POINT (L, Rch) (AF Assy) Adjustment Value � 8.2dBV Confirm that the reading is � 2.2 ± 2.5dBV. Remarks