It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
;
the manual is in good quality and it's in pdf. manual was send in less then 24h.
regards
mike
;
I would not plug this machine in without finding a manual like this. In addition to setup and normal operating instructions, it has troubleshooting flowcharts, diagrammed mechanical adjustments, and schematics to beat the band. The tech I hand it to would be thrilled to find solder side PCB diagrams with component outlines superimposed, pinouts for every IC chip, and line drawings of transistors, with labeled legs.
As for printing quality, this may be a copy of a copy, but even the finest print when enlarged is very legible. There is a bit of grayed print over a few pages, as if a wet page were placed over it, but the print is still very legible. If you could borrow an original manual and get it printed and bound for 4 to 6 times the cost, you could get better quality. In that case you wouldn't be here. For price, utility, and availability I am rating this manual highly.
3.JITTER CHECK 1) While oscilloscope is kept connected in the same test point as in step2. RF WAVEFORM CHECK, connect the output terminal of an oscilloscope to the input terminal of the jitter meter. 2) 3) 4) Set the VOLT range selector of oscilloscope to 500mV range or below. Play back 2nd track of TCD-782.
RF SW OUTPUT INPUT ns OSCILLOSCOPE JITTER METER
Check that jitter meter indicates 28.0ns or less.
Vref
4. PLAY ABILITY CHECK 1) Play back the 3rd , 8th and 13th track of ATD-001. Check that the noise does not occur sound skipping does not occur.
5.LASER CURRENT CHECK *Do not perform this measurement unless the laser is suspected to be defective. 1) 2) 3) Connect digital multi-meter across the resistor R402(10Ω). Play back the TCD-782 and check the DC voltage value on the digital multi-meter. Calculate the laser current (Iop) by dividing the DC voltage across R402 by the resistor value (R402= 10Ω). Check that the laser current (Iop) is 60mA or less.
R402 R402 DIGITAL MULTIMETER V