Who's Online
There currently are 5964 guests online.
|
Support Info
First point of contact:
All trademarks are the property of their respective owners
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Excellent service from this company (including a total refund on an earlier purchase when through no fault of the company the manual was incomplete). I have purchased several manuals which I have been very satisfied with, as I am with this one. Highly recommended.
;
It was easy to order and received exactly what I needed. Only complaint would be the 24 hours you have to wait.
;
Manual was delivered in a timely manner and was all in English as advertised. The manuals I received when we moved into our flat were in German, Italian, and French. Having never used a steamer before, and not speaking/reading German very well, I needed an English Manual. this was a huge help.
;
Great Manual. This manual is available no where else. It was exactly what I was looking for. Only in German.
;
This GRUNDIG UV5A Owner Manual is not only an instruction manual but a total functional circuit description of the Multimeter and includes circuit diagram at the end pages. It is very helpful for repairing and calibrating the instrument. It is written in two languages English and German for international support. It was very easy to repair my unit with this document. Regards, Regis Pauly, Electrical Engineer.
For healthier homes
45
2
6
Using Turbo nozzle or Power nozzle (some models)
s-bag� safety device To avoid damaging the cleaner do not use it without a dust bag. A safety device is fitted which prevents the cover closing without a dust bag. Do not attempt to force cover shut. Changing/Cleaning the filters These should be changed/cleaned every fifth dust bag. Never use the cleaner without the motor protection filter. To change Motor Protection filter: D) Release catch and swing back lid. E) Discard the unit. Put in new filter and close lid. To change Micro filter (some models): F) Open the filter cover. G) Discard the filter. Put in new filter unit and close lid. To clean HEPA filter (some models): H) Open filter cover and remove filter unit. I) Rinse the inside (dirty side) of the filter under warm tap water only. Do not use cleaning agents and avoid touching the delicate filter service. Tap the filter to remove excess water. Repeat cleaning procedure four times and allow the filter to air dry. The original filtering performance is now restored. Replace unit back into
Precautions: Only use nozzle on carpets with a pile depth under 15 mm. Do not use on animal skins or rugs with long fringes. To avoid damaging your carpet, do not keep nozzle stationary whilst brush is rotating. Do not pass nozzle over mains cable and switch off nozzle immediately after use. 7 8 9 10 Attach turbo nozzle or power nozzle to tubes. Connect power nozzle plug to power outlet on cleaner and use clips to secure cable to tube and hose. Power nozzle is activated by starting the cleaner. Suction can also be regulated on turbo nozzle by opening/closing air vent. Cleaning Turbo nozzle or Power nozzle (some models) 11 12 Disconnect from mains and remove entangled threads from nozzle by snipping threads with scissors. Insert screwdriver to remove power nozzle cover. Remove brush cylinder and supports. Clean as necessary and replace. To clean wheels, gently lever them from their mountings. 13 Replace cover ensuring it is properly fastened. Using combination nozzle/brush (some models) 14 15 16 Use in position shown for cleaning upholstery. Use in position shown for dusting. Attach to hose handle for storage. s-bag� indicator and changing the s-bag� For peak performance the s-bag� must be changed when full. If the dust bag should accidentally get broken in the cleaner, take cleaner to an Electrolux Service Centre for cleaning. The s-bag� indicator window will gradually turn red when filling and completely red when full. To check the s-bag�, the cleaner must be switched on, with all attachments connected and off the floor. The s-bag� full indicator may signify that the bag is blocked (occasionally caused by very fine dust) which will cause loss of suction and may result in overheating. If this occurs change the dust bag even if it is not full. To change the s-bag�: A) Release catch and swing back lid. B) Pull the sliding tab to remove the s-bag�. C) Insert the new s-bag� by sliding the bag slots onto the holder. Close lid. We recommend the s-bag� is changed: * * after using a carpet cleaning powder. if there is a bad smell from the cleaner, then you should also change/clean the filters. Note: Use only Electrolux original s-bags� and filters: s-bags� and motor protection filter (ref. E54) Micro filter (ref. EF17) Washable, reuseable HEPA filter (ref. EF26a). 19 18 17
cleaner and close cover.
Troubleshooting
Power: If the electric power does not come on, disconnect from mains and check plugs, cable and fuses where appropriate. Blockages/dirty filters: The cleaner may switch itself off in the event of a severe blockage or excessively dirty filter(s). In such cases, disconnect from mains and allow to cool for 2030 minutes. Clear blockage and/or replace filter(s) and restart. The clearing of blocked hoses is not covered by the guarantee. To avoid blockages and maintain suction efficiency, the floor nozzles should be cleaned regularly using the hose handle. Please also see Electrolux additional information towards the back of this booklet. Water: If water is sucked into the cleaner the motor must be changed at an Electrolux Service Centre. If you have any comments on the cleaner or the Instructions for use Booklet please e-mail us on: [email protected]
ANY PROBLEMS?
Something missing? Don�t understand the instructions? DON�T TAKE Need more help? We are only a telephone call away. CUSTOMER HELPLINE
IT BACK TO THE SHOP
08706 055 055
|
|
|
> |
|