This place is amazing. Got our manual in a few hours. Print quality is excellent. Even the manufacturer didn't have this manual. The price was excellent. How many more stars can I give them? More than satisfied.
This was a very hard to find manual. The unit is long discontinued and Pioneer doesn't retain every manual for every model. Thanks owner's-manual.com!
Text excerpt from page 9 (click to view)
Installation
Important
This cooker must be installed by qualified personnel. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.
Important
Upon completion of installation, always check: l that all the joints are completely sealed by using a soapy solution, never a flame; l that the gas pressure has been regulated to 1.00kPa for Natural Gas and 2.75kPa for Universal-LPG. The pressure test point is located on the regulator for Natural Gas models or at the top left hand rear of the cooker for U-LPG models. The pressure should be measured and adjusted with the Wok burner on high flame; l that the automatic ignition system is operating satisfactory on all burners, both individually and in combination; that the burners operate correctly, are stable, without l yellow tipping or excessive noise on high and low flame. operation and leave these instructions.
Regulations
This appliance shall be installed in accordance with the manufacturer�s installation instructions, local gas fitting and any other relevant statutory regulations.
regulations, municipal building codes, AS5601 (AG601)
Data label
The data label is located centrally on the back frame of the appliance. This appliance is suitable for Natural or Universal LPG. Ensure that the gas supply matches the data label. A duplicate of the data label is supplied in the packaging of the user manual and must be attached to readily accessible adjacent surfaces of the appliance.
Then demonstrate to the customer the appliance
Connection to the gas supply
Gas connection must be carried out in conformity with the regulations in force. The appliance leaves the factory tested and regulated for the type of gas indicated on the plate which is situated in the lower position near the gas connection tube. Ascertain that the type of gas with which the appliance will be supplied is the same as that indicated on the plate. If different carry out all the operations according to the indications cited in the paragraph �adaption to different types of gas�. For a maximum output and minimum consumption ascertain that the pressure of the gas used has the values indicated in the table of �burner characteristics�. The joint is mounted on the intake area of the pipe, fitted with a filleted nut G 1/2, between the sealing components. Screw the parts without forcing, turn the joint in the direction required and then tighten everything.
FO 0814
FO 0264
A) End of shaft with nut B) Washer C) Elbow
Connection
Carry out the connection to the gas plant only by means of a rigid metallic pipe conforming to the regulations in force. The joint for the entry of gas into the appliance is threaded R 1/2 tapered. Carry out the connection avoiding any type of stress on the appliance. Natural gas appliances must be fitted with a pressure regulator and be installed at the inlet connection. The gas pressure must then be set as a part of the commissioning procedures. For U-LPG the pressure adjustment is made via the regulator fitted at the domestic cylinder.